Showing posts with label excessive vacuum. Show all posts
Showing posts with label excessive vacuum. Show all posts

Thursday, August 13, 2015

Noise in Hydraulic System

Here's another Flint Hydraulics Tech Tip: Noise in a hydraulic system can mean serious trouble. A rattling sound from the pump may indicate cavitation of the fluid, caused by excessive vacuum at the pump's inlet. Even moderate cavitation can destroy a pump within a few hours of operation. What causes cavitation? It may be excessive pump shaft speed, high oil viscosity, a restriction or too many elbows in the inlet plumbing, or a collapsed inlet hose, among other causes. Need help troubleshooting? Contact any of our Certified Fluid Power Specialists today at 901-794-4884 or email sales@flinthyd.com.